{"id":41,"date":"2014-03-25T00:00:33","date_gmt":"2014-03-24T23:00:33","guid":{"rendered":"http:\/\/szkodliwepromieniowanie.pl\/?p=41"},"modified":"2014-04-28T12:38:00","modified_gmt":"2014-04-28T10:38:00","slug":"srodowisko-pracy","status":"publish","type":"post","link":"http:\/\/szkodliwepromieniowanie.pl\/?p=41","title":{"rendered":"\u015arodowisko pracy"},"content":{"rendered":"<h2 style=\"text-align: justify;\"><b>Zagro\u017cenia elektromagnetyczne w \u015brodowisku pracy.<\/b><\/h2>\n<p style=\"text-align: justify;\">Grupy zawodowe b\u0119d\u0105ce cz\u0119sto pod wp\u0142ywem dzia\u0142ania PEM mo\u017cemy podzieli\u0107 na pracownik\u00f3w pracuj\u0105cych w:<\/p>\n<p style=\"text-align: justify;\"><a data-postid=\"fsg_post_41\" data-imgid=\"172\" href=\"http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-1.png\"><img loading=\"lazy\" class=\" wp-image-172 aligncenter\" alt=\"\u015arodowisko pracy\" src=\"http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-1.png\" width=\"906\" height=\"368\" srcset=\"http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-1.png 906w, http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-1-300x121.png 300w\" sizes=\"(max-width: 906px) 100vw, 906px\" \/><\/a><\/p>\n<p style=\"text-align: justify;\">Oczywi\u015bcie przedstawiony podzia\u0142 nie obejmuje wszystkich pracownik\u00f3w.<\/p>\n<p style=\"text-align: justify;\">Opr\u00f3cz<b>\u00a0typowych<\/b>\u00a0zagro\u017ce\u0144 wyst\u0119puj\u0105cych r\u00f3wnie\u017c w \u015brodowisku naturalnym (rozdzielnie, linie\u00a0 energetyczne, \u0142\u0105czno\u015b\u0107 kom\u00f3rkowa) w wymienionych wy\u017cej miejscach wyst\u0119puj\u0105\u00a0<b>specyficzne<\/b>\u00a0<b>\u017ar\u00f3d\u0142a<\/b>charakterystycznedla okre\u015blonych stanowisk pracy. R\u00f3\u017cni\u0105 si\u0119 cz\u0119stotliwo\u015bci\u0105, sposobem promieniowania.<\/p>\n<p style=\"text-align: justify;\">W\u00a0<b>pomieszczeniach biurowych<\/b>\u00a0\u017ar\u00f3d\u0142em p\u00f3l elektromagnetycznych najcz\u0119\u015bciej\u00a0 jest sprz\u0119t komputerowy, urz\u0105dzenia \u0142\u0105czno\u015bci bezprzewodowej, instalacja elektryczna i ewentualnie zewn\u0119trzne \u017ar\u00f3d\u0142a zwi\u0105zane z nadajnikami.<\/p>\n<p style=\"text-align: justify;\"><a data-postid=\"fsg_post_41\" data-imgid=\"173\" href=\"http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-2.png\"><img loading=\"lazy\" class=\"size-full wp-image-173 alignleft\" alt=\"\u015arodowisko pracy\" src=\"http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-2.png\" width=\"265\" height=\"177\" \/><\/a><\/p>\n<p style=\"text-align: justify;\">Pracownicy maj\u0105 te\u017c cz\u0119sto do czynienia z polem elektrostatycznym. Warto\u015bci nat\u0119\u017ce\u0144 zmiennych p\u00f3l elektrycznych s\u0105 z regu\u0142y ma\u0142e. Bardziej istotne jest oddzia\u0142ywanie pola magnetycznego, szczeg\u00f3lnie ma\u0142ych cz\u0119stotliwo\u015bci (50\u00a0Hz\u00a0i harmonicznych). Warto\u015bci tego pola (indukcji magnetycznej)\u00a0<b>uzale\u017cnione s\u0105 od<\/b>\u00a0<b>warto\u015bc<\/b><strong>i<\/strong>\u00a0<b>p\u0142yn\u0105cego<\/b><b>\u00a0pr\u0105du<\/b>\u00a0i odleg\u0142o\u015bci zasilanych urz\u0105dze\u0144 elektrycznych od pracownika\u00a0<a title=\"mierniki pola elektromagnetycznego\" href=\"http:\/\/www.unitor.com.pl\/110-mierniki-pola-elektomagnetycznego\">tutaj<\/a>.<\/p>\n<p style=\"text-align: justify;\"><b><a data-postid=\"fsg_post_41\" data-imgid=\"174\" href=\"http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-3.png\"><img loading=\"lazy\" class=\"alignright size-full wp-image-174\" alt=\"\u015arodowisko pracy\" src=\"http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-3.png\" width=\"300\" height=\"239\" \/><\/a>Zgrzewarki dielektryczne<\/b>\u00a0s\u0142u\u017c\u0105ce do \u0142\u0105czenia\u00a0materia\u0142\u00f3w s\u0105 silnym \u017ar\u00f3d\u0142em pola elektrycznego w zakresie wy\u017cszych cz\u0119stotliwo\u015bci. Najcz\u0119\u015bciej, osoby obs\u0142uguj\u0105ce te urz\u0105dzenia znajduj\u0105 si\u0119 w bezpo\u015bredniej blisko\u015bci \u017ar\u00f3d\u0142a, przez ca\u0142y czas pracy. Trakcja kolejowa i elektrowozy to te\u017c \u017ar\u00f3d\u0142o p\u00f3l elektromagnetycznych. Podobnie ma to miejsce w komunikacji tramwajowej.<\/p>\n<p style=\"text-align: justify;\"><a data-postid=\"fsg_post_41\" data-imgid=\"175\" href=\"http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-4.jpg\"><img loading=\"lazy\" class=\"alignleft size-medium wp-image-175\" alt=\"\u015arodowisko pracy\" src=\"http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-4-300x256.jpg\" width=\"300\" height=\"256\" srcset=\"http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-4-300x256.jpg 300w, http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-4.jpg 703w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>W\u00a0<b>zak\u0142adach przemys\u0142owych<\/b>\u00a0i miejscach zwi\u0105zanych\u00a0z\u00a0<b>wytwarzaniem<\/b><b>\u00a0energii elektrycznej<\/b>, jej przesy\u0142aniem i rozdzia\u0142em, wyst\u0119puj\u0105\u00a0cz\u0119sto silne nat\u0119\u017cenia pola sk\u0142adowej elektrycznej i magnetycznej o cz\u0119stotliwo\u015bci 50\u00a0Hz. W pobli\u017cu urz\u0105dze\u0144 energetycznych, w zale\u017cno\u015bci od parametr\u00f3w (warto\u015bci napi\u0119\u0107 , pr\u0105d\u00f3w) mog\u0105 wyst\u0119powa\u0107 pola o poziomach strefy po\u015bredniej i zagro\u017cenia. W przypadku instalacji niskonapi\u0119ciowych g\u0142\u00f3wnym zagro\u017ceniem jest pole magnetyczne mierzone cz\u0119sto jako indukcja magnetyczna. Wiele urz\u0105dze\u0144 wykorzystywanych w zak\u0142adach (zgrzewarki oporowe, spawarki, piece \u0142ukowe) to \u017ar\u00f3d\u0142a p\u00f3l magnetostatycznych i pola magnetycznego z zakresu cz\u0119stotliwo\u015bci 50Hz-300\u00a0Hz, mog\u0105cych stanowi\u0107 zagro\u017cenie dla pracownik\u00f3w.<\/p>\n<p style=\"text-align: justify;\"><a data-postid=\"fsg_post_41\" data-imgid=\"176\" href=\"http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-5.jpg\"><img loading=\"lazy\" class=\"alignright  wp-image-176\" alt=\"\u015arodowisko pracy\" src=\"http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-5.jpg\" width=\"151\" height=\"240\" \/><\/a>W\u00a0<b>wojsku, s\u0142u\u017cbach policyjnych<\/b>\u00a0korzysta si\u0119 z wielu urz\u0105dze\u0144 do \u0142\u0105czno\u015bci bezprzewodowej pracuj\u0105cych na r\u00f3\u017cnych cz\u0119stotliwo\u015bciach i z\u00a0r\u00f3\u017cn\u0105 moc\u0105. Najcz\u0119\u015bciej s\u0105 to urz\u0105dzenia znajduj\u0105ce si\u0119 w bezpo\u015bredniej blisko\u015bci cia\u0142a przez wiele godzin. Radiolinie, urz\u0105dzenia radarowe, silne nadajniki radiowe to typowe urz\u0105dzenia b\u0119d\u0105ce \u017ar\u00f3d\u0142em p\u00f3l elektromagnetycznych. Niekt\u00f3re z tych urz\u0105dze\u0144 s\u0105 \u017ar\u00f3d\u0142em silnego\u00a0impulsowego\u00a0pola elektrycznego .<\/p>\n<p style=\"text-align: justify;\">W\u00a0<b>plac\u00f3wkach s\u0142u\u017cby zdrowia<\/b>\u00a0pracuje liczna grupa zawodowa codziennie obs\u0142uguj\u0105ca urz\u0105dzenia mog\u0105ce stanowi\u0107 istotne zagro\u017cenia. Du\u017ca cz\u0119\u015b\u0107 urz\u0105dze\u0144 do zabieg\u00f3w fizykoterapeutycznych jest \u017ar\u00f3d\u0142em pola magnetycznego ma\u0142ej\u00a0cz\u0119stotliwo\u015bci. S\u0105 to urz\u0105dzenia do magnetoterapii. Innego rodzaju urz\u0105dzenia zwane diatermiami s\u0105 \u017ar\u00f3d\u0142em silnych p\u00f3l elektrycznych i magnetycznych.<\/p>\n<p><img loading=\"lazy\" class=\"size-full wp-image-177 alignleft\" alt=\"\u015arodowisko pracy\" src=\"http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-6.png\" width=\"300\" height=\"141\" \/><\/p>\n<p style=\"text-align: justify;\">Urz\u0105dzenia rezonansu magnetycznego (tomografy RM) s\u0105 \u017ar\u00f3d\u0142em\u00a0bardzo silnego pola magnetostatycznego. Urz\u0105dzenia elektrochirurgiczne s\u0105 \u017ar\u00f3d\u0142em du\u017cych p\u00f3l elektrycznych i mog\u0105 w pewnych warunkach by\u0107 \u017ar\u00f3d\u0142em p\u00f3l magnetycznych. Operuj\u0105cy chirurg, cz\u0119sto przez wiele godzin nara\u017cony jest na dzia\u0142anie tych p\u00f3l, z oczywistych wzgl\u0119d\u00f3w nie zajmuj\u0105c si\u0119 optymalnym u\u0142o\u017ceniem kabli zapewniaj\u0105cym zmniejszenie nara\u017cenia. Z uwagi na wa\u017cno\u015b\u0107 zagadnienia, urz\u0105dzeniom medycznym po\u015bwi\u0119cono oddzieln\u0105 podstron\u0119<a title=\"plac\u00f3wki s\u0142u\u017cby zdrowia\" href=\"http:\/\/szkodliwepromieniowanie.pl\/zagrozenia-elektromagnetyczne-w-srodowisku\/placowki-sluzby-zdrowia\/\">\u00a0tutaj<\/a>.<\/p>\n<p style=\"text-align: justify;\">Pracownicy wykonuj\u0105cy czynno\u015bci w\u00a0<b>pobli\u017cu stacji nadawczych\u00a0<\/b>cz\u0119sto s\u0105 nara\u017ceni na dzia\u0142anie silnych PEM w czasie zabieg\u00f3w konserwacyjnych czy te\u017c instalacji nowych nadajnik\u00f3w i anten. Wiele system\u00f3w antenowych instalowanych jest jednocze\u015bnie na tych samych obiektach (wie\u017cach, kominach, masztach). Cz\u0119\u015b\u0107 nadajnik\u00f3w, mimo zmniejszonej mocy pracuje. W pobli\u017cu tych obiekt\u00f3w nast\u0119puje emisja PEM pochodz\u0105ca od urz\u0105dze\u0144 sieci kom\u00f3rkowej, nadajnik\u00f3w radiowych, radiolinii. Pracownicy wykonuj\u0105cy np. malowanie komina z zamontowanymi na nim antenami, mog\u0105 nie by\u0107 do ko\u0144ca \u015bwiadomi zagro\u017ce\u0144 wynikaj\u0105cych z dzia\u0142ania silnego pola elektromagnetycznego. R\u00f3wnie\u017c pracownicy wykonuj\u0105cy prac\u0119 przy u\u017cyciu metalowych d\u017awig\u00f3w, koparek, w pobli\u017cu silnych urz\u0105dze\u0144 nadawczych, mog\u0105 zaobserwowa\u0107 zak\u0142\u00f3cenia w pracy tych urz\u0105dze\u0144. Tego typu zak\u0142\u00f3cenia mog\u0105 stanowi\u0107 r\u00f3wnie\u017c zagro\u017cenie dla zdrowia pracownik\u00f3w.<\/p>\n<p style=\"text-align: justify;\">Stosowanie odpowiednich limit\u00f3w ochronnych w \u015brodowisku pracy jest wa\u017cnym elementem przyczyniaj\u0105cym si\u0119 do zmniejszenia zagro\u017ce\u0144 w miejscach oddzia\u0142ywania PEM. Dla cel\u00f3w BHP ustalono odpowiednie\u00a0 strefy zwane\u00a0<b>strefami oddzia\u0142ywania<\/b>.<\/p>\n<h2 style=\"text-align: justify;\"><b>STREFY ODDZIA\u0141YWANIA PEM<\/b><\/h2>\n<p style=\"text-align: justify;\">Strefy zosta\u0142y zdefiniowane dla warunk\u00f3w \u015brodowiska pracy i s\u0105 przedstawione w Rozporz\u0105dzeniu Ministra Pracy i Polityki Spo\u0142ecznej z dnia 29 listopada 2002r. w sprawie najwy\u017cszych dopuszczalnych st\u0119\u017ce\u0144 czynnik\u00f3w szkodliwych dla zdrowia\u00a0<b>w \u015brodowisku pracy<\/b>. Dziennik Ustaw nr 217\u00a0poz\u00a01833 2002 r.<br \/>\nRozporz\u0105dzenie w za\u0142\u0105czniku E odnosi si\u0119 do pola i promieniowania elektromagnetycznego w zakresie 0Hz do 300\u00a0GHz.<br \/>\nZ uwagi na operowanie warto\u015bciami nat\u0119\u017ce\u0144 pola elektrycznego i pola magnetycznego dla poszczeg\u00f3lnych\u00a0<b>istotnych<\/b>\u00a0pasm cz\u0119stotliwo\u015bci poni\u017cej w tabelach umieszczono charakterystyczne warto\u015bci p\u00f3l PEM w poszczeg\u00f3lnych strefach oddzia\u0142ywania.<\/p>\n<h3 style=\"text-align: justify;\">Tabela:\u00a0<b>STREFY ODDZIA\u0141YWANIA PEM<\/b><\/h3>\n<table width=\"641\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td rowspan=\"2\" valign=\"bottom\">Zakres cz\u0119stotliwo\u015bci<\/td>\n<td colspan=\"3\" valign=\"bottom\">Granica pomi\u0119dzy stref\u0105 bezpieczn\u0105 i po\u015bredni\u0105<\/td>\n<td colspan=\"3\" valign=\"bottom\">Granica pomi\u0119dzy stref\u0105 po\u015bredni\u0105 i zagro\u017cenia<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">E<sub>0<\/sub>\u00a0[V\/m]<\/td>\n<td valign=\"bottom\">H<sub>0<\/sub>\u00a0[A\/m]<\/td>\n<td valign=\"bottom\">B<sub>0\u00a0<\/sub>[uT]<\/td>\n<td valign=\"bottom\">E<sub>1<\/sub>\u00a0[V\/m]<\/td>\n<td valign=\"bottom\">H<sub>1<\/sub>\u00a0[A\/m]<\/td>\n<td valign=\"bottom\">B<sub>1<\/sub>\u00a0[uT]<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" width=\"152\">0\u00a0Hz\u2264 f \u2264 0,5Hz pola elektrostatyczne i magnetostatyczne<\/td>\n<td valign=\"bottom\">10000<\/td>\n<td valign=\"bottom\">2666<\/td>\n<td valign=\"bottom\">3333<\/td>\n<td valign=\"bottom\">20000<\/td>\n<td valign=\"bottom\">8000<\/td>\n<td valign=\"bottom\">10000<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\"><strong>0,5\u00a0Hz\u00a0&lt; f \u2264 50\u00a0Hz<\/strong><\/td>\n<td valign=\"bottom\"><strong>5000<\/strong><\/td>\n<td valign=\"bottom\"><strong>67<\/strong><\/td>\n<td valign=\"bottom\"><strong>83<\/strong><\/td>\n<td valign=\"bottom\"><strong>10000<\/strong><\/td>\n<td valign=\"bottom\"><strong>200<\/strong><\/td>\n<td valign=\"bottom\"><strong>250<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">50\u00a0Hz\u00a0&lt; f \u22640,3 kHz<\/td>\n<td valign=\"bottom\">5000<\/td>\n<td valign=\"bottom\">3,3\/f<\/td>\n<td valign=\"bottom\">4,1\/f<\/td>\n<td valign=\"bottom\">10000<\/td>\n<td valign=\"bottom\">10\/f<\/td>\n<td valign=\"bottom\">12,5\/f<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">0,3 kHz &lt; f \u2264 1 kHz<\/td>\n<td valign=\"bottom\">33\/f<\/td>\n<td valign=\"bottom\">3,3\/f<\/td>\n<td valign=\"bottom\">4,1\/f<\/td>\n<td valign=\"bottom\">100\/f<\/td>\n<td valign=\"bottom\">10\/f<\/td>\n<td valign=\"bottom\">12,5\/f<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">1 kHz &lt; f \u2264 0,8 MHz<\/td>\n<td valign=\"bottom\">33,3<\/td>\n<td valign=\"bottom\">3,33<\/td>\n<td valign=\"bottom\">4,1<\/td>\n<td valign=\"bottom\">100<\/td>\n<td valign=\"bottom\">10<\/td>\n<td valign=\"bottom\">12,5<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">0,8 MHz &lt; f \u2264 3 MHz<\/td>\n<td valign=\"bottom\">33,3<\/td>\n<td valign=\"bottom\">2,6\/f<\/td>\n<td valign=\"bottom\">3,33\/f<\/td>\n<td valign=\"bottom\">100<\/td>\n<td valign=\"bottom\">8\/f<\/td>\n<td valign=\"bottom\">10\/f<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">3 MHz &lt; f \u2264 15 MHz<\/td>\n<td valign=\"bottom\">100\/f<\/td>\n<td valign=\"bottom\">2,6\/f<\/td>\n<td valign=\"bottom\">3,33\/f<\/td>\n<td valign=\"bottom\">300\/f<\/td>\n<td valign=\"bottom\">8\/f<\/td>\n<td valign=\"bottom\">10\/f<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">15 MHz&lt; f \u2264150 MHz<\/td>\n<td valign=\"bottom\">6,7<\/td>\n<td valign=\"bottom\">2,6\/f<\/td>\n<td valign=\"bottom\">3,33\/f<\/td>\n<td valign=\"bottom\">20<\/td>\n<td valign=\"bottom\">8\/f<\/td>\n<td valign=\"bottom\">10\/f<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">0,15\u00a0GHz&lt; f \u2264 3\u00a0GHz<\/td>\n<td valign=\"bottom\">6,7<\/td>\n<td valign=\"bottom\">0,017<\/td>\n<td valign=\"bottom\">0,022<\/td>\n<td valign=\"bottom\">20<\/td>\n<td valign=\"bottom\">0,053<\/td>\n<td valign=\"bottom\">0,066<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">3\u00a0GHz\u00a0&lt; f \u2264 300\u00a0GHz<\/td>\n<td valign=\"bottom\">0,053 f + 6,5<\/td>\n<td valign=\"bottom\">\u2014\u2014-<\/td>\n<td valign=\"bottom\">\u2014\u2014-<\/td>\n<td valign=\"bottom\">0,16 f + 19,5<\/td>\n<td valign=\"bottom\">\u2014\u2014-<\/td>\n<td valign=\"bottom\">\u2014\u2014-<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table width=\"641\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td rowspan=\"2\" valign=\"bottom\">Zakres cz\u0119stotliwo\u015bci<\/td>\n<td colspan=\"3\" valign=\"bottom\">Granica pomi\u0119dzy stref\u0105 zagro\u017cenia i niebezpieczn\u0105<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">E<sub>2<\/sub>\u00a0[V\/m]<\/td>\n<td valign=\"bottom\">H<sub>2<\/sub>[A\/m]<\/td>\n<td valign=\"bottom\">B<sub>2\u00a0<\/sub>[uT]<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\" width=\"147\">0\u00a0Hz\u00a0\u2264 f \u2264 0,5\u00a0Hz\u00a0pola elektrostatyczne i magnetostatyczne<\/td>\n<td valign=\"bottom\" width=\"129\">40 000<\/td>\n<td valign=\"bottom\" width=\"98\">80 000<\/td>\n<td valign=\"bottom\" width=\"80\">100 500<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\"><strong>0,5\u00a0Hz\u00a0&lt; f \u2264 50\u00a0Hz<\/strong><\/td>\n<td valign=\"bottom\"><strong>20 000<\/strong><\/td>\n<td valign=\"bottom\"><strong>2 000<\/strong><\/td>\n<td valign=\"bottom\"><strong>2 513<\/strong><\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">0,05 kHz &lt; f \u2264 0,3 kHz<\/td>\n<td valign=\"bottom\" width=\"129\">20 000<\/td>\n<td valign=\"bottom\" width=\"98\">100\/f<\/td>\n<td valign=\"bottom\" width=\"80\">126\/f<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">0,3 kHz &lt; f \u2264 1 kHz<\/td>\n<td valign=\"bottom\" width=\"129\">1000\/f<\/td>\n<td valign=\"bottom\" width=\"98\">100\/f<\/td>\n<td valign=\"bottom\" width=\"80\">126\/f<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">1 kHz &lt; f \u2264 0,8 MHz<\/td>\n<td valign=\"bottom\" width=\"129\">1000<\/td>\n<td valign=\"bottom\" width=\"98\">100<\/td>\n<td valign=\"bottom\" width=\"80\">126<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">0,8 MHz &lt; f \u2264 3 MHz<\/td>\n<td valign=\"bottom\" width=\"129\">1000<\/td>\n<td valign=\"bottom\" width=\"98\">80\/f<\/td>\n<td valign=\"bottom\" width=\"80\">100\/f<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">3 MHz &lt; f \u2264 15 MHz<\/td>\n<td valign=\"bottom\" width=\"129\">3000\/f<\/td>\n<td valign=\"bottom\" width=\"98\">80\/f<\/td>\n<td valign=\"bottom\" width=\"80\">100\/f<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">15 MHz &lt; f \u2264 150 MHz<\/td>\n<td valign=\"bottom\" width=\"129\">200<\/td>\n<td valign=\"bottom\" width=\"98\">80\/f<\/td>\n<td valign=\"bottom\" width=\"80\">100\/f<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">0,15\u00a0GHz\u00a0&lt; f \u2264 3\u00a0GHz<\/td>\n<td valign=\"bottom\">200<\/td>\n<td valign=\"bottom\">0,53<\/td>\n<td valign=\"bottom\">0,67<\/td>\n<\/tr>\n<tr>\n<td valign=\"bottom\">3\u00a0GHz\u00a0&lt; f \u2264 300\u00a0GHz<\/td>\n<td valign=\"bottom\" width=\"129\">1,6 f + 195<\/td>\n<td valign=\"bottom\" width=\"98\">\u2014\u2014-<\/td>\n<td valign=\"bottom\" width=\"80\">\u2014\u2014-<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: justify;\">Uwagi:<br \/>\n<strong>E<sub>0<\/sub>, H<sub>0<\/sub><\/strong>\u00a0\u2013 nat\u0119\u017cenie p\u00f3l o cz\u0119stotliwo\u015bci f rozgraniczaj\u0105ce stref\u0119 po\u015bredni\u0105 od strefy bezpiecznej<br \/>\n<strong>E<sub>1<\/sub>, H<sub>1<\/sub><\/strong>\u00a0-nat\u0119\u017cenie p\u00f3l o cz\u0119stotliwo\u015bci f rozgraniczaj\u0105ce stref\u0119 zagro\u017cenia od strefy po\u015bredniej<br \/>\n<strong>E<sub>2<\/sub>, H<sub>2<\/sub><\/strong>\u00a0-nat\u0119\u017cenie p\u00f3l o cz\u0119stotliwo\u015bci f rozgraniczaj\u0105ce stref\u0119 niebezpieczn\u0105 od strefy zagro\u017cenia<br \/>\n<strong>f<\/strong> \u2013 cz\u0119stotliwo\u015b\u0107 w jednostkach podanych w kolumnie \u201ezakres cz\u0119stotliwo\u015bci\u201d;<br \/>\n<strong>E<\/strong> \u2013 nat\u0119\u017cenie pola elektrycznego;<br \/>\n<strong>H<\/strong> \u2013 nat\u0119\u017cenie pola magnetycznego;<br \/>\n<strong>B<\/strong> \u2013 indukcja magnetyczna<br \/>\n<strong>Zale\u017cno\u015b\u0107 pomi\u0119dzy jednostkami indukcji i pola<\/strong>: 1 A\/m -&gt; 1,2563\u00a0uT, czyli 1uT -&gt; 0,796 A\/m ( w pr\u00f3\u017cni i powietrzu )<\/p>\n<p style=\"text-align: justify;\"><b>UWAGA<\/b>: Nat\u0119\u017cenia strefy bezpiecznej w \u015brodowisku pracy s\u0105 zbli\u017cone do dopuszczalnych nat\u0119\u017ce\u0144 p\u00f3\u0142 dla miejsc dost\u0119pnych dla og\u00f3\u0142u ludno\u015bci w \u015brodowisku naturalnym.<\/p>\n<p style=\"text-align: justify;\"><b>Ekspozycja w strefie zagro\u017cenia musi spe\u0142nia\u0107 dodatkowe warunki dotycz\u0105ce tzw. dozy rzeczywistej i wska\u017anika ekspozycji.<\/b><br \/>\nW przypadku, gdy ekspozycja dotyczy p\u00f3l impulsowych w pa\u015bmie 0,1\u00a0GHz\u00a0do 300\u00a0GHz\u00a0nale\u017cy jeszcze dodatkowo uwzgl\u0119dni\u0107 warunki dotycz\u0105ce\u00a0<b>maksymalnych warto\u015bci pola elektrycznego w impulsie<\/b>.<br \/>\nWymienione warto\u015bci graniczne i poj\u0119cia przedstawione s\u0105 w Rozporz\u0105dzeniu Ministra Zdrowia.<a title=\"rozporz\u0105dzenie Ministra Zdrowia\" href=\"http:\/\/szkodliwepromieniowanie.pl\/regulacje-prawne\/\">\u00a0tutaj<\/a><\/p>\n<h3 style=\"text-align: justify;\"><b>GRAFICZNE PRZEDSTAWIENIE STREF ODDZIA\u0141YWANIA<\/b><\/h3>\n<p style=\"text-align: justify;\"><a data-postid=\"fsg_post_41\" data-imgid=\"178\" href=\"http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-7.png\"><img loading=\"lazy\" class=\"aligncenter size-full wp-image-178\" alt=\"\u015arodowisko pracy\" src=\"http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-7.png\" width=\"599\" height=\"575\" srcset=\"http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-7.png 599w, http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-7-300x287.png 300w\" sizes=\"(max-width: 599px) 100vw, 599px\" \/><\/a><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #ff0000;\">STREFA NIEBEZPIECZNA<\/span>\u00a0-obszar, w kt\u00f3rym z zasady przebywanie\u00a0pracownik\u00f3w jest zabronione,\u00a0dopuszczalne jedynie pod warunkiem stosowania\u00a0\u015brodk\u00f3w ochrony osobistej<br \/>\n<span style=\"color: #ff9900;\">STREFA ZAGRO\u017bENIA<\/span>\u00a0&#8211; obszar, w kt\u00f3rym przebywanie pracownik\u00f3w jest dopuszczone w ograniczonym czasie i zgodnie z okre\u015blonymi zasadami<br \/>\n<span style=\"color: #ffff00;\">STREFA PO\u015aREDNIA<\/span>\u00a0&#8211;\u00a0obszar, w kt\u00f3rym przebywanie pracownik\u00f3w jest dopuszczone w ci\u0105gu ca\u0142ej zmiany roboczej<br \/>\n<span style=\"color: #99cc00;\">STREFA BEZPIECZNA<\/span>\u00a0&#8211; obszar poza zasi\u0119giem stref ochronnych<\/p>\n<h2 style=\"text-align: justify;\"><b>CZ\u0118STOTLIWO\u015a\u0106 WYKONYWANIA POMIAR\u00d3W P\u00d3L<\/b><b><br \/>\n<\/b><\/h2>\n<p style=\"text-align: justify;\"><a data-postid=\"fsg_post_41\" data-imgid=\"179\" href=\"http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-8.png\"><img loading=\"lazy\" class=\"alignleft size-full wp-image-179\" alt=\"\u015arodowisko pracy\" src=\"http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-8.png\" width=\"652\" height=\"371\" srcset=\"http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-8.png 652w, http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-8-300x170.png 300w\" sizes=\"(max-width: 652px) 100vw, 652px\" \/><\/a><\/p>\n<h2 style=\"text-align: justify;\"><b>ZAPOBIEGANIE ZAGRO\u017bENIOM<\/b><\/h2>\n<p style=\"text-align: justify;\"><b><a href=\"http:\/\/unitor.com.pl\/309-tm-192-trojosiowy-miernik-pola-elektromagnetycznego-.html\"><img loading=\"lazy\" class=\"alignleft size-full wp-image-180\" alt=\"\u015arodowisko pracy\" src=\"http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-9.png\" width=\"300\" height=\"137\" \/><\/a>W \u015brodowisku pracy<\/b>\u00a0jest stosunkowo \u0142atwo ustali\u0107 zagro\u017cenia wynikaj\u0105ce z oddzia\u0142ywania PEM. Pewnym utrudnieniem jest r\u00f3\u017cnorodno\u015b\u0107 pracuj\u0105cych w pobli\u017cu siebie urz\u0105dze\u0144 i zmienno\u015b\u0107 charakteru ich pracy.<br \/>\nZgodnie z odpowiednimi przepisami\u00a0<a title=\"przepisy prawne\" href=\"http:\/\/szkodliwepromieniowanie.pl\/regulacje-prawne\/\">tutaj,<\/a>\u00a0obszary wyst\u0119powania silnych p\u00f3l elektromagnetycznych i obszary wok\u00f3\u0142 nich, jako strefy ochronne, powinny by\u0107 odpowiednio wyznaczane i oznakowane. Podstawow\u0105 zasad\u0105 powinno by\u0107 ograniczanie czasu przebywania pracownik\u00f3w w strefie potencjalnego zagro\u017cenia i w miar\u0119 mo\u017cliwo\u015bci wykonywanie czynno\u015bci jak najdalej od samego \u017ar\u00f3d\u0142a promieniowania.<\/p>\n<p style=\"text-align: justify;\"><a data-postid=\"fsg_post_41\" data-imgid=\"181\" href=\"http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-10.jpg\"><img loading=\"lazy\" class=\"alignright  wp-image-181\" alt=\"\u015arodowisko pracy\" src=\"http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-10.jpg\" width=\"192\" height=\"192\" srcset=\"http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-10.jpg 300w, http:\/\/szkodliwepromieniowanie.pl\/wp-content\/uploads\/srodowisko-pracy-10-150x150.jpg 150w\" sizes=\"(max-width: 192px) 100vw, 192px\" \/><\/a>Stosowanie odpowiednich urz\u0105dze\u0144, w\u0142a\u015bciwa organizacja pracy, automatyzacja proces\u00f3w produkcyjnych, u\u017cywanie kamer do zdalnej\u00a0obserwacji s\u0105 istotnymi czynnikami zmniejszaj\u0105cymi ekspozycj\u0119 pracownik\u00f3w na PEM. Warto zaznaczy\u0107, i\u017c ju\u017c na etapie\u00a0<b>projektowania maszyn<\/b>, stosuj\u0105c si\u0119 do zasad zwanych ,,dobr\u0105 sztuk\u0105 in\u017cyniersk\u0105\u201d mo\u017cna znacznie zmniejszy\u0107 poziomy warto\u015bci PEM.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Zagro\u017cenia elektromagnetyczne w \u015brodowisku pracy. Grupy zawodowe b\u0119d\u0105ce cz\u0119sto pod wp\u0142ywem dzia\u0142ania PEM mo\u017cemy podzieli\u0107 na pracownik\u00f3w pracuj\u0105cych w: Oczywi\u015bcie przedstawiony podzia\u0142 nie obejmuje wszystkich pracownik\u00f3w. Opr\u00f3cz\u00a0typowych\u00a0zagro\u017ce\u0144 wyst\u0119puj\u0105cych r\u00f3wnie\u017c w \u015brodowisku naturalnym (rozdzielnie, linie\u00a0 energetyczne, \u0142\u0105czno\u015b\u0107 kom\u00f3rkowa) w wymienionych wy\u017cej miejscach wyst\u0119puj\u0105\u00a0specyficzne\u00a0\u017ar\u00f3d\u0142acharakterystycznedla okre\u015blonych stanowisk pracy. R\u00f3\u017cni\u0105 si\u0119 cz\u0119stotliwo\u015bci\u0105, sposobem promieniowania. W\u00a0pomieszczeniach biurowych\u00a0\u017ar\u00f3d\u0142em p\u00f3l elektromagnetycznych najcz\u0119\u015bciej\u00a0 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[1],"tags":[],"_links":{"self":[{"href":"http:\/\/szkodliwepromieniowanie.pl\/index.php?rest_route=\/wp\/v2\/posts\/41"}],"collection":[{"href":"http:\/\/szkodliwepromieniowanie.pl\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/szkodliwepromieniowanie.pl\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/szkodliwepromieniowanie.pl\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/szkodliwepromieniowanie.pl\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=41"}],"version-history":[{"count":8,"href":"http:\/\/szkodliwepromieniowanie.pl\/index.php?rest_route=\/wp\/v2\/posts\/41\/revisions"}],"predecessor-version":[{"id":236,"href":"http:\/\/szkodliwepromieniowanie.pl\/index.php?rest_route=\/wp\/v2\/posts\/41\/revisions\/236"}],"wp:attachment":[{"href":"http:\/\/szkodliwepromieniowanie.pl\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=41"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/szkodliwepromieniowanie.pl\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=41"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/szkodliwepromieniowanie.pl\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=41"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}